HBProducts | Liquid Level Sensors | IECEx & ATEx Sensors Zone 0 & 1 | HFC HFO CFC
Technical data: HBLC-HFC
HBLC-HFC capacitive liquid level sensors are used to measure liquid levels e.g. HFC, HFO & CFC in industrial systems. The sensor transmits a current signal from 4 to 20 mA (4 mA when the transmitter does not register liquid - and 20 mA when the entire transmitter is surrounded by liquid).HBLT-A2 capacitive liquid level sensors are used to measure liquid levels in vessels.
The sensor is designed in stainless steel and can be used in corrosive environments. The sensor must be supplied with 24 V DC through an Ex-barrier, which must be an approved and certifided galvanically isolated interface barrier placed outside the hazardous area. The sensor is a 2-wire design with analog output with 4 mA (empti tank) and 20 mA (full tank). The analog output shall be connected to the Ex-barrier. The Ex-barrier is not sccope of supply.
The sensor can be set-up for liquid type in the HB-Tool which can be downloaded from our web-page. See HB-Tool. Diagnostic is as well a possibility with the tool. The programming must be carried out in an non hazardous area.
The sensor range include sensors for zone 0 and 1 according to ATEX/IECEx. The sensors can be used in device category 1G and temperature class T1...T6.
A 5 m cable with M12 plug type IEC61076-2-101 is included.
Product features
- Temperature range: -40...+70°C.
- Max pressure: 150 bar
- ATEX / IECEx: Ex ia IIC T1…T6 Ga (Ta = -40°C to +70°C)
- Excellent liquid and gas compatibility
- Cost effective alternative to ultrasonic & radar sensor technologies
- Works with reflective liquids
- Will not fail due to vapor
- No galvanic corrosion
- Split design which makes it easy to install and make diagnostic.
Applications
- Process plants
- Storage tanks
Intrinsically Safe design:
Intrinsically Safe (IS) sensors are designed and wired to work on such a low current and voltage that it cannot possibly ignite flammable material. By limiting the energy available within the defined hazardous area, electrical equipment can operate safely even amid hazardous mixtures of gasses.
The HBLC sensor is designed for many kinds of liquidsbased on the dielectric constant. The liquid type is selected in the HB-Tool.
The measuring principle and the influence of the dielectric constant:
Capacitors are designed with minimum two conductors, where one of them is electric isolated. The dielectric constant are key for operation of capacitors, the capacity size is measured in pF.
Dielectric constant (Relative permittivity) is a unique value on a scale of 1 to 100. The value can be seen as a media’s DNA, because it`s unique and related to the molecular structure and polarization.
The Dielectric Constant is always greater than or equal to 1. The larger the dielectric constant, the more charge can be stored (like a battery).
The dielectric constant changes with temperature and pressure, the sensor comes with automatic temperature compensation calibrated/adapted to the measured media.
Type of sensors:
Sensor type | Liquid type | Dielectric constant |
HBLC-CO2 | CO2(R744), Butane (R600), Isobutane (R600A), Propane (R290) | 1.5-2.0 |
HBLC-OIL | PAO oil, Mineral oil, POE oil, PAG oil | 2.0-4.0 |
HBLC-HFC | R507, R410a, R407c, R404a, R22, R32, R134a, R1234yf, R1234ze | 4.0-10.0 |
HBLT-A2 | NH3, Water, R717, R718, Alchohol | 10.0-80.0 |

Note: When used in EX-area the installation has to be carried out accourding to standards in force for the country in question.
The equipment must be electrically connected via an approved and certified galvanically isolated interface barrier placed outside the hazardous area.
Specification

Power supply | Output | ||
Voltage | 12-28 V DC two wire | Signal output | 4...20 mA (AO) |
Max. current consumption | Max 20 mA | Mechanical specifications | |
Plug connections | M12, 5 pins - DIN 0627 | Material liquid parts | AISI 304 / PTFE |
Ex area | Material electronic parts | Nylon 6 (PA) | |
IECEx classification | Ex ia IIC T1…T6 Ga | Environmental conditions | |
Device category | 1G for Zone 0 & 1 | Max pressure | 100 bar |
Type of protection | ia | Protection degree | IP66 |
Gas resp. gas group | IIC | Vibrations | IEC 60068-2-6 (4g) |
Temperature class | T1….T6 | EMC | EN 61000 |
Ambient temperature | -40...+50°C/+70°C |
When used in Ex-area the installation has to be carried out according to standards in force for the country in question.
The Equipment must be installed via an approved and certified galvanically interface barrier placed outside the hazardous area.
Ordering Code
Length | Thread type | ATEX/IECEx approval | Ordering code | Length | Thread type | ATEX/IECEx approval | Ordering code
|
200 mm | 3/4” NPT | Zone 0 & 1 | HBLC-HFC-2-2-EX | 1100 mm | 3/4” NPT | Zone 0 & 1 | HBLC-HFC-11-2-EX
|
200 mm | 3/4” BSPP | Zone 0 & 1 | HBLC-HFC-2-6-EX | 1100 mm | 3/4” BSPP | Zone 0 & 1 | HBLC-HFC-11-6-EX
|
300 mm | 3/4” NPT | Zone 0 & 1 | HBLC-HFC-3-2-EX | 1200 mm | 3/4” NPT | Zone 0 & 1 | HBLC-HFC-12-2-EX
|
300 mm | 3/4” BSPP | Zone 0 & 1 | HBLC-HFC-3-6-EX | 1200 mm | 3/4” BSPP | Zone 0 & 1 | HBLC-HFC-12-6-EX
|
400 mm | 3/4” NPT | Zone 0 & 1 | HBLC-HFC-4-2-EX | 1300 mm | 3/4” NPT | Zone 0 & 1 | HBLC-HFC-13-2-EX
|
400 mm | 3/4” BSPP | Zone 0 & 1 | HBLC-HFC-4-6-EX | 1300 mm | 3/4” BSPP | Zone 0 & 1 | HBLC-HFC-13-6-EX
|
500 mm | 3/4” NPT | Zone 0 & 1 | HBLC-HFC-5-2-EX | 1400 mm | 3/4” NPT | Zone 0 & 1 | HBLC-HFC-14-2-EX
|
500 mm | 3/4” BSPP | Zone 0 & 1 | HBLC-HFC-5-6-EX | 1400 mm | 3/4” BSPP | Zone 0 & 1 | HBLC-HFC-14-6-EX
|
600 mm | 3/4” NPT | Zone 0 & 1 | HBLC-HFC-6-2-EX | 1500 mm | 3/4” NPT | Zone 0 & 1 | HBLC-HFC-15-2-EX
|
600 mm | 3/4” BSPP | Zone 0 & 1 | HBLC-HFC-6-6-EX | 1500 mm | 3/4” BSPP | Zone 0 & 1 | HBLC-HFC-15-6-EX
|
700 mm | 3/4” NPT | Zone 0 & 1 | HBLC-HFC-7-2-EX | 1700 mm | 3/4” NPT | Zone 0 & 1 | HBLC-HFC-17-2-EX
|
700 mm | 3/4” BSPP | Zone 0 & 1 | HBLC-HFC-7-6-EX | 1700 mm | 3/4” BSPP | Zone 0 & 1 | HBLC-HFC-17-6-EX
|
800 mm | 3/4” NPT | Zone 0 & 1 | HBLC-HFC-8-2-EX | 2000 mm | 3/4” NPT | Zone 0 & 1 | HBLC-HFC-20-2-EX
|
800 mm | 3/4” BSPP | Zone 0 & 1 | HBLC-HFC-8-6-EX | 2000 mm | 3/4” BSPP | Zone 0 & 1 | HBLC-HFC-20-6-EX
|
900 mm | 3/4” NPT | Zone 0 & 1 | HBLC-HFC-9-2-EX | 2500 mm | 3/4” NPT | Zone 0 & 1 | HBLC-HFC-25-2-EX
|
900 mm | 3/4” BSPP | Zone 0 & 1 | HBLC-HFC-9-6-EX | 2500 mm | 3/4” BSPP | Zone 0 & 1 | HBLC-HFC-25-6-EX
|
1000 mm | 3/4” NPT | Zone 0 & 1 | HBLC-HFC-10-2-EX | 3000 mm | 3/4” NPT | Zone 0 & 1 | HBLC-HFC-30-2-EX
|
1000 mm | 3/4” BSPP | Zone 0 & 1 | HBLC-HFC-10-6-EX | 3000 mm | 3/4” BSPP | Zone 0 & 1 | HBLC-HFC-30-6-EX
|
Download
Realated Products